{"product_id":"sensidyne-gilian-silica-sampling-kits","title":"Sensidyne Gilian Silica Sampling Kits","description":"\u003ch3 data-end=\"341\" data-start=\"317\"\u003e\u003cstrong data-end=\"341\" data-start=\"321\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"703\" data-start=\"343\"\u003eThe Gilian® Silica Sampling Kits from Sensidyne are purpose-built for industrial hygienists and safety professionals conducting compliant Respirable Crystalline Silica (RCS) sampling. Each kit provides a complete, efficient, and accurate solution that meets NMAM 7500 and OSHA silica standards, reducing setup time and ensuring precise results.\u003c\/p\u003e\n\u003cp data-end=\"1093\" data-start=\"705\"\u003eAvailable in Basic, Standard, and Advanced configurations, these kits combine the trusted Gilian sampling pumps (GilAir 3 or GilAir Plus) with pre-weighed filters and industry-standard cyclones for size-selective sampling. The Advanced Kit includes the GK2.69 Cyclone, offering higher flow rates and the ability to connect directly to a calibrator, no calibration jar required.\u003c\/p\u003e\n\u003cp data-end=\"1321\" data-start=\"1095\"\u003eThese kits make silica exposure monitoring simpler, more compliant, and more reliable—ideal for occupational health professionals working in construction, quarrying, mining, manufacturing, and other high-dust environments.\u003c\/p\u003e\n\u003ch3 data-end=\"1358\" data-start=\"1328\"\u003e\u003cstrong data-end=\"1358\" data-start=\"1332\"\u003eProduct Configurations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"1978\" data-start=\"1360\"\u003e\n\u003cthead data-end=\"1462\" data-start=\"1360\"\u003e\n\u003ctr data-end=\"1462\" data-start=\"1360\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1370\" data-start=\"1360\"\u003e\u003cstrong data-end=\"1369\" data-start=\"1362\"\u003eKit\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1381\" data-start=\"1370\"\u003e\u003cstrong data-end=\"1380\" data-start=\"1372\"\u003ePump\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1403\" data-start=\"1381\"\u003e\u003cstrong data-end=\"1402\" data-start=\"1383\"\u003eCyclone\/Sampler\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1419\" data-start=\"1403\"\u003e\u003cstrong data-end=\"1418\" data-start=\"1405\"\u003eFlow Rate\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1438\" data-start=\"1419\"\u003e\u003cstrong data-end=\"1437\" data-start=\"1421\"\u003eFilter Media\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1462\" data-start=\"1438\"\u003e\u003cstrong data-end=\"1460\" data-start=\"1440\"\u003eIncluded Filters\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"1978\" data-start=\"1571\"\u003e\n\u003ctr data-end=\"1681\" data-start=\"1571\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1587\" data-start=\"1571\"\u003e\u003cstrong data-end=\"1586\" data-start=\"1573\"\u003eBasic Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1598\" data-start=\"1587\"\u003eGilAir 3\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1612\" data-start=\"1598\"\u003eDorr-Oliver\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1622\" data-start=\"1612\"\u003e1.7 LPM\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1647\" data-start=\"1622\"\u003e37mm, 5.0 Micron, 3-pc\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1681\" data-start=\"1647\"\u003e5 pre-weighed filter cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1828\" data-start=\"1682\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1701\" data-start=\"1682\"\u003e\u003cstrong data-end=\"1700\" data-start=\"1684\"\u003eStandard Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1745\" data-start=\"1701\"\u003eGilAir Plus (with clock and data logging)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1759\" data-start=\"1745\"\u003eDorr-Oliver\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1769\" data-start=\"1759\"\u003e1.7 LPM\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1794\" data-start=\"1769\"\u003e37mm, 5.0 Micron, 3-pc\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1828\" data-start=\"1794\"\u003e5 pre-weighed filter cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1978\" data-start=\"1829\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1848\" data-start=\"1829\"\u003e\u003cstrong data-end=\"1847\" data-start=\"1831\"\u003eAdvanced Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1892\" data-start=\"1848\"\u003eGilAir Plus (with clock and data logging)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1909\" data-start=\"1892\"\u003eGK2.69 Cyclone\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1919\" data-start=\"1909\"\u003e4.2 LPM\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1944\" data-start=\"1919\"\u003e37mm, 5.0 Micron, 3-pc\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1978\" data-start=\"1944\"\u003e5 pre-weighed filter cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cblockquote data-end=\"2199\" data-start=\"1980\"\u003e\n\u003cp data-end=\"2199\" data-start=\"1982\"\u003e\u003cstrong data-end=\"1991\" data-start=\"1982\"\u003eNote:\u003c\/strong\u003e Air flow calibrator not included.\u003cbr data-end=\"2028\" data-start=\"2025\"\u003eDorr-Oliver cyclone kits require a calibration jar (P\/N 7013376, not included).\u003cbr data-end=\"2112\" data-start=\"2109\"\u003eThe GK2.69 cyclone connects directly to a calibrator, eliminating the need for a jar.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3 data-end=\"2237\" data-start=\"2206\"\u003e\u003cstrong data-end=\"2237\" data-start=\"2210\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2756\" data-start=\"2239\"\u003e\n\u003cli data-end=\"2299\" data-start=\"2239\"\u003e\n\u003cp data-end=\"2299\" data-start=\"2241\"\u003e✅ \u003cstrong data-end=\"2297\" data-start=\"2243\"\u003eCompliant with OSHA and NMAM 7500 silica standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2381\" data-start=\"2300\"\u003e\n\u003cp data-end=\"2381\" data-start=\"2302\"\u003e✅ \u003cstrong data-end=\"2325\" data-start=\"2304\"\u003eThree kit options\u003c\/strong\u003e to fit a range of budgets and monitoring requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2450\" data-start=\"2382\"\u003e\n\u003cp data-end=\"2450\" data-start=\"2384\"\u003e✅ \u003cstrong data-end=\"2409\" data-start=\"2386\"\u003ePre-weighed filters\u003c\/strong\u003e streamline sampling and lab submission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2522\" data-start=\"2451\"\u003e\n\u003cp data-end=\"2522\" data-start=\"2453\"\u003e✅ \u003cstrong data-end=\"2472\" data-start=\"2455\"\u003eHigh accuracy\u003c\/strong\u003e for both thoracic and respirable dust fractions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2603\" data-start=\"2523\"\u003e\n\u003cp data-end=\"2603\" data-start=\"2525\"\u003e✅ \u003cstrong data-end=\"2553\" data-start=\"2527\"\u003eRugged and field-ready\u003c\/strong\u003e components designed for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2690\" data-start=\"2604\"\u003e\n\u003cp data-end=\"2690\" data-start=\"2606\"\u003e✅ \u003cstrong data-end=\"2647\" data-start=\"2608\"\u003eAdvanced data logging (GilAir Plus)\u003c\/strong\u003e for traceable results and improved QA\/QC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2756\" data-start=\"2691\"\u003e\n\u003cp data-end=\"2756\" data-start=\"2693\"\u003e✅ \u003cstrong data-end=\"2721\" data-start=\"2695\"\u003eSimplified calibration\u003c\/strong\u003e with GK2.69 cyclone (Advanced Kit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2783\" data-start=\"2763\"\u003e\u003cstrong data-end=\"2783\" data-start=\"2767\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3012\" data-start=\"2785\"\u003e\n\u003cli data-end=\"2833\" data-start=\"2785\"\u003e\n\u003cp data-end=\"2833\" data-start=\"2787\"\u003eRespirable Crystalline Silica (RCS) sampling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2870\" data-start=\"2834\"\u003e\n\u003cp data-end=\"2870\" data-start=\"2836\"\u003eOccupational hygiene assessments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2923\" data-start=\"2871\"\u003e\n\u003cp data-end=\"2923\" data-start=\"2873\"\u003eConstruction, quarrying, and mining environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2965\" data-start=\"2924\"\u003e\n\u003cp data-end=\"2965\" data-start=\"2926\"\u003eManufacturing and material processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3012\" data-start=\"2966\"\u003e\n\u003cp data-end=\"3012\" data-start=\"2968\"\u003eRegulatory compliance (OSHA, HSE, NMAM 7500)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3031\" data-start=\"3019\"\u003e\u003cstrong data-end=\"3031\" data-start=\"3023\"\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3273\" data-start=\"3033\"\u003e\u003cstrong data-end=\"3092\" data-start=\"3033\"\u003eQ: What is included in each Gilian Silica Sampling Kit?\u003c\/strong\u003e\u003cbr data-end=\"3095\" data-start=\"3092\"\u003eEach kit includes a Gilian sampling pump, pre-weighed filter media (five cassettes), and the appropriate cyclone or sampler. The air flow calibrator must be purchased separately.\u003c\/p\u003e\n\u003cp data-end=\"3354\" data-start=\"3275\"\u003e\u003cstrong data-end=\"3352\" data-start=\"3275\"\u003eQ: What is the difference between the Basic, Standard, and Advanced kits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"3598\" data-start=\"3355\"\u003e\n\u003cli data-end=\"3427\" data-start=\"3355\"\u003e\n\u003cp data-end=\"3427\" data-start=\"3357\"\u003e\u003cem data-end=\"3364\" data-start=\"3357\"\u003eBasic\u003c\/em\u003e: Entry-level kit with GilAir 3 pump and Dorr-Oliver cyclone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3491\" data-start=\"3428\"\u003e\n\u003cp data-end=\"3491\" data-start=\"3430\"\u003e\u003cem data-end=\"3440\" data-start=\"3430\"\u003eStandard\u003c\/em\u003e: Adds clock and data logging (GilAir Plus pump).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3598\" data-start=\"3492\"\u003e\n\u003cp data-end=\"3598\" data-start=\"3494\"\u003e\u003cem data-end=\"3504\" data-start=\"3494\"\u003eAdvanced\u003c\/em\u003e: Includes GilAir Plus pump and GK2.69 cyclone for higher flow rates and jar-free calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3784\" data-start=\"3600\"\u003e\u003cstrong data-end=\"3635\" data-start=\"3600\"\u003eQ: Do I need a calibration jar?\u003c\/strong\u003e\u003cbr data-end=\"3638\" data-start=\"3635\"\u003eYes, the Basic and Standard kits (Dorr-Oliver cyclone) require a calibration jar (sold separately). The Advanced kit with GK2.69 cyclone does not.\u003c\/p\u003e\n\u003cp data-end=\"3936\" data-start=\"3786\"\u003e\u003cstrong data-end=\"3821\" data-start=\"3786\"\u003eQ: Are the filters pre-weighed?\u003c\/strong\u003e\u003cbr data-end=\"3824\" data-start=\"3821\"\u003eYes, all kits include five pre-weighed 37mm, 5.0-micron, 3-piece filter cassettes for compliant silica sampling.\u003c\/p\u003e\n\u003cp data-end=\"4109\" data-start=\"3938\"\u003e\u003cstrong data-end=\"3980\" data-start=\"3938\"\u003eQ: Which standards do these kits meet?\u003c\/strong\u003e\u003cbr data-end=\"3983\" data-start=\"3980\"\u003eThe Gilian Silica Sampling Kits comply with \u003cstrong data-end=\"4052\" data-start=\"4027\"\u003eOSHA silica standards\u003c\/strong\u003e and \u003cstrong data-end=\"4078\" data-start=\"4057\"\u003eNIOSH Method 7500\u003c\/strong\u003e requirements for RCS sampling.\u003c\/p\u003e\n\u003ch3 data-end=\"4140\" data-start=\"4116\"\u003e\u003cstrong data-end=\"4140\" data-start=\"4120\"\u003eAvailable Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"4155\" data-start=\"4142\"\u003e\u003cstrong data-end=\"4155\" data-start=\"4142\"\u003eBasic Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4275\" data-start=\"4156\"\u003e\n\u003cli data-end=\"4215\" data-start=\"4156\"\u003e\n\u003cp data-end=\"4215\" data-start=\"4158\"\u003e910-2411-00UK-R – GilAir3, Dorr-Oliver Cyclone, UK Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4293\" data-start=\"4277\"\u003e\u003cstrong data-end=\"4293\" data-start=\"4277\"\u003eStandard Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4417\" data-start=\"4294\"\u003e\n\u003cli data-end=\"4357\" data-start=\"4294\"\u003e\n\u003cp data-end=\"4357\" data-start=\"4296\"\u003e910-2412-00UK-R – GilAir Plus, Dorr-Oliver Cyclone, UK Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4435\" data-start=\"4419\"\u003e\u003cstrong data-end=\"4435\" data-start=\"4419\"\u003eAdvanced Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"4554\" data-start=\"4436\"\u003e\n\u003cli data-end=\"4494\" data-start=\"4436\"\u003e\n\u003cp data-end=\"4494\" data-start=\"4438\"\u003e910-2413-00UK-R – GilAir Plus, GK2.69 Cyclone, UK Cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4853\" data-start=\"4592\"\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eConcrete cutting, drilling and grinding\u003c\/li\u003e\n  \u003cli\u003eMasonry and demolition\u003c\/li\u003e\n  \u003cli\u003eTunnelling and road construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eMining, Quarrying \u0026amp; Oil\/Gas Extraction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRock drilling and crushing\u003c\/li\u003e\n  \u003cli\u003eFrac sand handling\u003c\/li\u003e\n  \u003cli\u003eHydraulic fracturing operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eFoundries\u003c\/li\u003e\n  \u003cli\u003eGlass manufacturing\u003c\/li\u003e\n  \u003cli\u003eCeramics and stone fabrication\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaritime \u0026amp; Abrasive Blasting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSurface preparation\u003c\/li\u003e\n  \u003cli\u003eShipyard abrasive blasting\u003c\/li\u003e\n  \u003cli\u003eConfined-space blasting work\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDental Laboratories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePorcelain grinding\u003c\/li\u003e\n  \u003cli\u003eInvestment casting\u003c\/li\u003e\n  \u003cli\u003eDental technician dust exposure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eAgriculture\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSoil dust exposure\u003c\/li\u003e\n  \u003cli\u003eDry tilling operations\u003c\/li\u003e\n  \u003cli\u003eDiatomaceous earth handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePro Tips for Silica Sampling\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e1. Calibrate the Cyclone Correctly\u003c\/strong\u003e\u003cbr\u003e\nAlways calibrate the cyclone before sampling to ensure accurate respirable particle collection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Monitor Pump Back Pressure\u003c\/strong\u003e\u003cbr\u003e\nHigh dust loading can clog filters and reduce flow rates. Monitor pumps regularly during sampling.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Keep the Cyclone Vertical\u003c\/strong\u003e\u003cbr\u003e\nThe cyclone must remain vertical throughout sampling to maintain proper particle separation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e4. Use the Correct Laboratory Method\u003c\/strong\u003e\u003cbr\u003e\nUse XRD or FTIR analysis methods such as NIOSH 7500 or 7602 for crystalline silica analysis.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e5. Use the Correct Flow Rate\u003c\/strong\u003e\u003cbr\u003e\nAlways calibrate the cyclone at the manufacturer-recommended flow rate: 1.7 L\/min for a Dorr-Oliver cyclone and 4.2 L\/min for a GK2.69 cyclone.\u003c\/p\u003e","brand":"Sensidyne","offers":[{"title":"Basic Kit","offer_id":56314034848127,"sku":"910-2411-00UK-R","price":780.0,"currency_code":"GBP","in_stock":true},{"title":"Standard Kit","offer_id":56848013328767,"sku":"910-2412-00UK-R","price":1119.2,"currency_code":"GBP","in_stock":true},{"title":"Advanced Kit","offer_id":56848016540031,"sku":"910-2413-00UK-R","price":1713.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0555\/2901\/3401\/files\/silicasampling.png?v=1761839160","url":"https:\/\/products.shawcity.co.uk\/products\/sensidyne-gilian-silica-sampling-kits","provider":"Shawcity","version":"1.0","type":"link"}